All Māhele
PRP & PRF Centrifuge

PRP & PRF Centrifuge

Home > Nā huahana- TJNE > Nā kenekulia > PRP & PRF Centrifuge

Platelet Rich Plasma Centrifuga PRF Blood Laboratory Centrifuge Machine

noi: Nā Halemaʻi, Nā Kauka Laʻau Laʻau, Nā Keʻena Meaʻai, Nā Kulanui a me nā Koleke, Nā Laʻau Laʻau Laʻau, Nā Keʻena Moʻomeheu Cell
Māmā 4000 rpm
Max. RCF 1900xg
Max.Capacity 8 * 10ml rotor kihi paʻa 8x10 / 5ml
Nā Rotor Kaulike Rotor kihi paʻa
make LCD
Model Number: PRP450
palapala hoʻomaikaʻi: CE, ISO13485, ISO9001, SFDA
palapala hoʻokō 1 makahiki palapala hoʻokō no ka mīkini holoʻokoʻa, 3 makahiki palapala hoʻokō no ka compressor a me 5 makahiki palapala hoʻokō no ka kaʻa. Nā ʻāpana pani manuahi a me ka hoʻouna ʻana i loko o ka palapala hōʻoia.
  • Description
  • Video
  • Nā Kūlana Kiʻi
  • Rotors a me na mea komo
  • ʻO ka pono kūpono

Haʻahaʻa māmā centrifuge PRP450 hoʻohana ʻia no ka hoʻokaʻawale ʻana a me ka hoʻomaʻemaʻe ʻana i nā mea ma muli o ko lākou nui a me ko lākou nui. He mau mea hana koʻikoʻi lākou ma nā ʻoihana ʻepekema a me nā ʻoihana lapaʻau he nui, e ʻae ana i nā mea noiʻi a me nā kānaka ʻepekema e aʻo a hoʻomaopopo i nā kaʻina hana olaola a me nā kemika like ʻole.

Design

● ʻO ka hale ABS, ke ola lōʻihi, maʻalahi e hoʻomaʻemaʻe a me ke keʻena centrifuge kila kila he mau mea holoi a me nā wai disinfection hiki ke hoʻohana ʻia i ka autoclave a kūpaʻa.

● puka makani nānā ma ka poʻi no ka hoʻoponopono ʻana i ka wikiwiki a me ke ana kani.

● Ka mana microprocessor me ka hoʻololi pinepine ʻana i ka kaʻa kaʻa AC

● LCD Hōʻike i nā palena o ka Speed, Timer, RCF, Rotors, Program(Memory), Acceleration & Deceleration information and Error code information.

● ʻO ke apo hoʻopaʻa paʻa pālua i hana ʻia no ka poʻi centrifuge a me ka mea kani e mālama i ka sila maikaʻi lōʻihi.

● ʻO ka mea nui no nā hoʻāʻo PRP/CGF/A-PRF/I-PRF, kūpono no ka syringe injection 10ml, nā paipu 5ml/8ml/10ml etc.

● Polokalamu wikiwiki loli kūikawā i kūkulu ʻia no PRP/CGF/A-PRF/I-PR, maʻalahi ke kiʻi hou. ʻO ka papahana mea kūʻai aku i mālama ʻia no nā mea hoʻohana e hoʻonohonoho.

● Liʻiliʻi a lawe lima ʻia, kūpono no ka hoʻohana ʻana i ke kelepona paʻalima, hoʻolālā maikaʻi.

TPRP4-S: Centrifuge wikiwiki haʻahaʻa

Mea launa hoʻohana

● Programmable a storable, hale kūʻai a hiki i 30 polokalamu a hāʻawi pololei mea hoʻohana me ka hoʻokahi kī kī. ʻO ka ʻāpana i mālama ʻia: hoʻomau ka hui ʻana i ka hoʻomanaʻo ma hope o ka pau ʻana o ka centrifugation.

● Hāʻawi i ka 10 acceleration rates a me 10 braking ramp, i mea e pale pono ai i ka sedimentation lua, me ka hopena centrifugation maikaʻi.

● Hoʻopaʻa paʻa ʻakomi a paʻa i ka wā holo rotor

● Hiki ke hoʻololi i nā rotor, mea hoʻohui rotor kūikawā e maʻalahi ai ka hoʻouka a me ka wehe ʻana i ka rotor.

● Hoʻoponopono pilikia 'akomi me ka hōʻike ʻana i ka helu kuhi hewa a me ka hoʻāla ma ka pale.

● "Mute" ʻenehana patent. ʻO ka haʻahaʻa haʻahaʻa o ka walaʻau ma mua o 58 decibel ma ka wikiwiki hoʻololi kiʻekiʻe.

● Huli 'akomi rpm/rcf

● ʻO ka ʻōnaehana hōʻike rotor maʻamau, ʻo ka ʻike rotor coded e pale i ka rotor mai ka holo wikiwiki ʻana.

TPRP4-S: Centrifuge wikiwiki haʻahaʻa

Maukele

● Hana ʻia e like me nā lula palekana honua (e laʻa me IEC 61010)

● Palekana Uila pani pani, ʻaʻole hiki ke wehe ʻia ka puka i ka wā e holo ana ka rotor a ʻaʻole holo ka mīkini i ka wehe ʻana o ka poʻi a ʻike ʻia ke code hewa.

● Hoʻokuʻu ʻia ka poʻi ulia pōpilikia i ka wā pau ʻole o ka mana (pono loa i ka pau ʻana o ka mana i manaʻo ʻole ʻia).

● Hine kinoea no ka pale hāʻule ʻana o ke poʻi.

● Hana ʻia nā pale palekana no ka wikiwiki, ma luna o ka hoʻomehana (motor, chamber), imbalance etc e hōʻoia i ka palekana o ka mīkini kanaka.

TPRP4-S: Centrifuge wikiwiki haʻahaʻa

Laulā māmā (rpm) 0-4000rpm hiki ke hoʻololi Hoʻololi i ka manawa 1-99minutes 59s hiki ke hoʻololi
Kaha Nui (ml) 8 * 10ml ʻO ka wikiwiki ± 10r / min
Laulā RCF (xg) 0-1900xg hiki ke hoʻololi ACC/DEC 1-10 uku
Noise (dBA) ≦50dB(A) Uuna paona (me ka rotor ole) 7KGS
Lako ikehu AC220V, 50HZ, 10A, 60W Ana (mm) 315x275x210mm(LxWxH)
ʻAʻole. 'ikamu Max. hiki Max. ka wikiwiki Max.RCF palapala aie

NO.1

Kahi inoa-8

Rotor kihi 8x10/5ml 4000r / min 1900xg Paipu PP/PC
Kahi inoa-1

1.Professional centrifuge mea hana, hoʻokūkū kumukūʻai.

2.ISO9001, ISO13485, CE, SFDA Certification, nā mīkini a pau e ho'āʻo maikaʻi i ka maikaʻi a me ka hōʻailona maikaʻi ma mua o ka laweʻana.

3.Long-manawa kākoʻo 'enehana a me ka 'oihana mea kūʻai aku lawelawe ma kela a me keia pae o ka huahana kuai, haawi aku a me ka hana.Our kiʻekiʻe loa qualified a me ka 'ike pūʻulu lawelawe e hoʻolako 'oe i kahi kūlana kūikawā o ke kākoʻo no kou kuai no ka mea, ola a pau.

4. Hiki iā mākou ke hāʻawi aku i nā hoʻoponopono hoʻoponopono no nā koi kūikawā o nā mea kūʻai.

5.Powered me kahi hui kūpono o nā 'enekinia i kākoʻoʻia e nā makahiki o kaʻike ma ko lākou mauʻoihana, e hōʻoiaʻiʻo ana ka hui i kēlā me kēia huahana e haʻalele i ka'āpana hana i ka hōʻailona ma nāʻano a pau.

KA NUI
0
ʻIe hīnaʻi
    Ua make ʻole kāu pahu noiʻi
Hoʻopauninau