NA HALE KUPUNI
PRP Centrifuge PRF/CGF Multi-functional Variable Speed Machine
| noi: | Nā Halemai, Nā Kauka Laʻau Laʻau, Nā Keʻena Meaʻai, Nā Kulanui a me nā Koleke, Nā Laʻau Laʻau Laʻau, Nā Pūnaewele Culture Cell, hale nani |
| Māmā | 6000 rpm |
| Max. RCF | 4588xg |
| Max.Capacity | 8 * 100ml |
| Nā Rotor Kaulike | ʻO ka rotor kihi paʻa, kāwele i waho |
| make | LCD |
| Model Number: | TD5B |
| palapala hoʻomaikaʻi: | CE, ISO13485, ISO9001, SFDA |
| palapala hoʻokō | 1 makahiki palapala hoʻokō no ka mīkini holoʻokoʻa, 3 makahiki palapala hoʻokō no ka compressor a me 5 makahiki palapala hoʻokō no ka kaʻa. Nā ʻāpana pani manuahi a me ka hoʻouna ʻana i loko o ka palapala hōʻoia. |
- Description
- Nā Kūlana Kiʻi
- Rotors a me na mea komo
- ʻO ka pono kūpono
Hoʻohana ʻia ka centrifuge haʻahaʻa haʻahaʻa TD5B no ka hoʻokaʻawale ʻana a me ka hoʻomaʻemaʻe ʻana i nā mea ma muli o ko lākou nui a me ka nui. He mau mea paahana ko lakou ma na kula epekema a me na laau lapaau, e hiki ai i na mea noii a me na kanaka epekema ke a'o a hoomaopopo i na ka'ina hana olaola a me kemika. Hoʻohana nui ʻia i ka ʻoihana orthopedics, ʻoihana ʻeha, ʻoihana ʻokiʻoki, cosmetology lapaʻau a me nā mea ʻē aʻe. ʻO ka PRP / ACT ka nui o ka ulu ʻana, hiki ke wikiwiki i ka hoʻihoʻi ʻana o ka ʻiʻo palupalu a me ka iwi iwi, hoʻemi i ka hopena postoperative, anti-infection, hiki nō hoʻi i ka ʻili hou.
Design
● Metala hale a me kuhiliʻole kila centrifuge keʻena he autoclave-hiki a me ke kūpaʻa detergents a me disinfection wai.
● puka makani nānā ma ka poʻi no ka hoʻoponopono ʻana i ka wikiwiki a me ke ana kani.
● Ka mana microprocessor me ka hoʻololi pinepine ʻana i ka kaʻa kaʻa AC
● LCD Hōʻike i nā palena o ka Speed, Timer, RCF, Rotors, Program(Memory), Acceleration & Deceleration information and Error code information.
● ʻO ke apo hoʻopaʻa paʻa pālua i hana ʻia no ka poʻi centrifuge a me ka mea kani e mālama i ka sila maikaʻi lōʻihi.
● Nā polokalamu 25 i mālamaʻia, hiki ke hoʻololi i waena o RPR, CGF, APRF, IPRF.
● Papahana wikiwiki hoʻololi i kūkulu ʻia, kūpono no 60ml / 20ml / 10ml / 8ml injection syringe a i ʻole PRP kaʻawale.
● Hiki ke ho'oma'ema'e 'ia nā bākeke, nā mea ho'ololi a me nā rotors e ka wela ki'eki'e.

Mea launa hoʻohana
● Programmable a storable, hale kūʻai a hiki i 30 polokalamu a hāʻawi pololei mea hoʻohana me ka hoʻokahi kī kī. ʻO ka ʻāpana i mālama ʻia: hoʻomau ka hui ʻana i ka hoʻomanaʻo ma hope o ka pau ʻana o ka centrifugation.
●Provides the 10 acceleration rates and 10 braking ramp, to effectively avoid secondary sedimentation, with better centrifugation effect.
●Automatic lid-locking and holding during rotor run
●Easily exchangeable rotors, special rotor connector which makes it easy to load and unload rotor.
● Hoʻoponopono pilikia 'akomi me ka hōʻike ʻana i ka helu kuhi hewa a me ka hoʻāla ma ka pale.
● "Mute" ʻenehana patent. ʻO ka haʻahaʻa haʻahaʻa o ka walaʻau ma mua o 58 decibel ma ka wikiwiki hoʻololi kiʻekiʻe.
● Huli 'akomi rpm/rcf
● ʻO ka ʻōnaehana hōʻike rotor maʻamau, ʻo ka ʻike rotor coded e pale i ka rotor mai ka holo wikiwiki ʻana.

Maukele
● Hana ʻia e like me nā lula palekana honua (e laʻa me IEC 61010)
● Palekana Uila pani pani, ʻaʻole hiki ke wehe ʻia ka puka i ka wā e holo ana ka rotor a ʻaʻole holo ka mīkini i ka wehe ʻana o ka poʻi a ʻike ʻia ke code hewa.
● Hoʻokuʻu ʻia ka poʻi ulia pōpilikia i ka wā pau ʻole o ka mana (pono loa i ka pau ʻana o ka mana i manaʻo ʻole ʻia).
● Hine kinoea no ka pale hāʻule ʻana o ke poʻi.
● Hana ʻia nā pale palekana no ka wikiwiki, ma luna o ka hoʻomehana (motor, chamber), imbalance etc e hōʻoia i ka palekana o ka mīkini kanaka.

| Laulā māmā (rpm) | 0-6000rpm hiki ke hoʻololi | Hoʻololi i ka manawa | 1-99minutes 59s hiki ke hoʻololi |
| Kaha Nui (ml) | 8 * 100ml | ʻO ka wikiwiki | ± 10r / min |
| Laulā RCF (xg) | 0-4588xg hiki ke hoʻololi | ACC/DEC | 1-10 uku |
| Noise (dBA) | ≦58dB(A) | Uuna paona (me ka rotor ole) | 40KGS |
| Lako ikehu | AC220V, 50HZ, 10A, 570W | Ana (mm) | 620x440x360mm(LxWxH) |
| ʻAʻole. | 'ikamu | Max. hiki | Max. ka wikiwiki | Max.RCF | palapala aie |
|
NO.1
|
Rotor kihi | 12x15/10/5ml | 6000r / min | 4588xg | Paipu PP/PC |
| mea hoʻopili | 12x2ml | Paipu PP/PC | |||
|
NO.2
|
Rotor swing | kila kila rotor | 4000r / min | 3041xg | Paipu PP/PC |
| Kaʻa koʻi | 4x100ml | Paipu PP/PC | |||
| mea hoʻopili | 4x50ml | Paipu PP/PC | |||
| mea hoʻopili | 4x20ml | Paipu PP/PC | |||
| mea hoʻopili | 4x8/10ml | Paipu PP/PC | |||
|
NO.3
|
Rotor swing | kila kila rotor | 4000r / min | 3041xg | Injection syringe a i ʻole PRP tube |
| Kaʻa koʻi | 4x2x100ml | Paipu PP/PC | |||
| mea hoʻopili | 4x2x100ml | Paipu PP/PC | |||
| mea hoʻopili | 4x2x20ml | Paipu PP/PC | |||
| mea hoʻopili | 4x2x8/10ml | Paipu PP/PC | |||
![]() | |||||
1.Professional centrifuge mea hana, hoʻokūkū kumukūʻai.
2.ISO9001, ISO13485, CE, SFDA Certification, nā mīkini a pau e ho'āʻo maikaʻi i ka maikaʻi a me ka hōʻailona maikaʻi ma mua o ka laweʻana.
3.Long-manawa kākoʻo 'enehana a me ka 'oihana mea kūʻai aku lawelawe ma kela a me keia pae o ka huahana kuai, haawi aku a me ka hana.Our kiʻekiʻe loa qualified a me ka 'ike pūʻulu lawelawe e hoʻolako 'oe i kahi kūlana kūikawā o ke kākoʻo no kou kuai no ka mea, ola a pau.
4. Hiki iā mākou ke hāʻawi aku i nā hoʻoponopono hoʻoponopono no nā koi kūikawā o nā mea kūʻai.
5.Powered me kahi hui kūpono o nā 'enekinia i kākoʻoʻia e nā makahiki o kaʻike ma ko lākou mauʻoihana, e hōʻoiaʻiʻo ana ka hui i kēlā me kēia huahana e haʻalele i ka'āpana hana i ka hōʻailona ma nāʻano a pau.

EN
AR
BG
HR
CS
DA
NL
FI
FR
DE
EL
IT
JA
KO
NO
PL
PT
RO
RU
ES
SV
CA
TL
IW
ID
LV
LT
SR
SK
SL
VI
SQ
HU
MT
TH
TR
FA
AF
MS
GA
BE
AZ
KA
MN
KK
UZ





















