All Māhele
PRP & PRF Centrifuge

PRP & PRF Centrifuge

Home > Nā huahana- TJNE > Nā kenekulia > PRP & PRF Centrifuge

PRP Centrifuge PRF/CGF Multi-functional Variable Speed ​​Machine

noi: Nā Halemai, Nā Kauka Laʻau Laʻau, Nā Keʻena Meaʻai, Nā Kulanui a me nā Koleke, Nā Laʻau Laʻau Laʻau, Nā Pūnaewele Culture Cell, hale nani
Māmā 6000 rpm
Max. RCF 4588xg
Max.Capacity 8 * 100ml
Nā Rotor Kaulike ʻO ka rotor kihi paʻa, kāwele i waho
make LCD
Model Number: TD5B
palapala hoʻomaikaʻi: CE, ISO13485, ISO9001, SFDA
palapala hoʻokō 1 makahiki palapala hoʻokō no ka mīkini holoʻokoʻa, 3 makahiki palapala hoʻokō no ka compressor a me 5 makahiki palapala hoʻokō no ka kaʻa. Nā ʻāpana pani manuahi a me ka hoʻouna ʻana i loko o ka palapala hōʻoia.
  • Description
  • Nā Kūlana Kiʻi
  • Rotors a me na mea komo
  • ʻO ka pono kūpono

Hoʻohana ʻia ka centrifuge haʻahaʻa haʻahaʻa TD5B no ka hoʻokaʻawale ʻana a me ka hoʻomaʻemaʻe ʻana i nā mea ma muli o ko lākou nui a me ka nui. He mau mea paahana ko lakou ma na kula epekema a me na laau lapaau, e hiki ai i na mea noii a me na kanaka epekema ke a'o a hoomaopopo i na ka'ina hana olaola a me kemika. Hoʻohana nui ʻia i ka ʻoihana orthopedics, ʻoihana ʻeha, ʻoihana ʻokiʻoki, cosmetology lapaʻau a me nā mea ʻē aʻe. ʻO ka PRP / ACT ka nui o ka ulu ʻana, hiki ke wikiwiki i ka hoʻihoʻi ʻana o ka ʻiʻo palupalu a me ka iwi iwi, hoʻemi i ka hopena postoperative, anti-infection, hiki nō hoʻi i ka ʻili hou.

Design

● Metala hale a me kuhiliʻole kila centrifuge keʻena he autoclave-hiki a me ke kūpaʻa detergents a me disinfection wai.

● puka makani nānā ma ka poʻi no ka hoʻoponopono ʻana i ka wikiwiki a me ke ana kani.

● Ka mana microprocessor me ka hoʻololi pinepine ʻana i ka kaʻa kaʻa AC

● LCD Hōʻike i nā palena o ka Speed, Timer, RCF, Rotors, Program(Memory), Acceleration & Deceleration information and Error code information.

● ʻO ke apo hoʻopaʻa paʻa pālua i hana ʻia no ka poʻi centrifuge a me ka mea kani e mālama i ka sila maikaʻi lōʻihi.

● Nā polokalamu 25 i mālamaʻia, hiki ke hoʻololi i waena o RPR, CGF, APRF, IPRF.

● Papahana wikiwiki hoʻololi i kūkulu ʻia, kūpono no 60ml / 20ml / 10ml / 8ml injection syringe a i ʻole PRP kaʻawale.

● Hiki ke ho'oma'ema'e 'ia nā bākeke, nā mea ho'ololi a me nā rotors e ka wela ki'eki'e.

TPRP4-M: Haʻahaʻa māmā Centrifuge

Mea launa hoʻohana

● Programmable a storable, hale kūʻai a hiki i 30 polokalamu a hāʻawi pololei mea hoʻohana me ka hoʻokahi kī kī. ʻO ka ʻāpana i mālama ʻia: hoʻomau ka hui ʻana i ka hoʻomanaʻo ma hope o ka pau ʻana o ka centrifugation.

●Provides the 10 acceleration rates and 10 braking ramp, to effectively avoid secondary sedimentation, with better centrifugation effect.

●Automatic lid-locking and holding during rotor run

●Easily exchangeable rotors, special rotor connector which makes it easy to load and unload rotor.

● Hoʻoponopono pilikia 'akomi me ka hōʻike ʻana i ka helu kuhi hewa a me ka hoʻāla ma ka pale.

● "Mute" ʻenehana patent. ʻO ka haʻahaʻa haʻahaʻa o ka walaʻau ma mua o 58 decibel ma ka wikiwiki hoʻololi kiʻekiʻe.

● Huli 'akomi rpm/rcf

● ʻO ka ʻōnaehana hōʻike rotor maʻamau, ʻo ka ʻike rotor coded e pale i ka rotor mai ka holo wikiwiki ʻana.

TPRP4-M: Haʻahaʻa māmā Centrifuge

Maukele

● Hana ʻia e like me nā lula palekana honua (e laʻa me IEC 61010)

● Palekana Uila pani pani, ʻaʻole hiki ke wehe ʻia ka puka i ka wā e holo ana ka rotor a ʻaʻole holo ka mīkini i ka wehe ʻana o ka poʻi a ʻike ʻia ke code hewa.

● Hoʻokuʻu ʻia ka poʻi ulia pōpilikia i ka wā pau ʻole o ka mana (pono loa i ka pau ʻana o ka mana i manaʻo ʻole ʻia).

● Hine kinoea no ka pale hāʻule ʻana o ke poʻi.

● Hana ʻia nā pale palekana no ka wikiwiki, ma luna o ka hoʻomehana (motor, chamber), imbalance etc e hōʻoia i ka palekana o ka mīkini kanaka.

TPRP4-M: Haʻahaʻa māmā Centrifuge
Laulā māmā (rpm) 0-6000rpm hiki ke hoʻololi Hoʻololi i ka manawa 1-99minutes 59s hiki ke hoʻololi
Kaha Nui (ml) 8 * 100ml ʻO ka wikiwiki ± 10r / min
Laulā RCF (xg) 0-4588xg hiki ke hoʻololi ACC/DEC 1-10 uku
Noise (dBA) ≦58dB(A) Uuna paona (me ka rotor ole) 40KGS
Lako ikehu AC220V, 50HZ, 10A, 570W Ana (mm) 620x440x360mm(LxWxH)
ʻAʻole. 'ikamu Max. hiki Max. ka wikiwiki Max.RCF palapala aie

NO.1

2

Rotor kihi 12x15/10/5ml 6000r / min 4588xg Paipu PP/PC
mea hoʻopili 12x2ml Paipu PP/PC

NO.2

5

Rotor swing kila kila rotor 4000r / min 3041xg Paipu PP/PC
Kaʻa koʻi 4x100ml Paipu PP/PC
mea hoʻopili 4x50ml Paipu PP/PC
mea hoʻopili 4x20ml Paipu PP/PC
mea hoʻopili 4x8/10ml Paipu PP/PC

NO.3

3

Rotor swing kila kila rotor 4000r / min 3041xg Injection syringe a i ʻole PRP tube
Kaʻa koʻi 4x2x100ml Paipu PP/PC
mea hoʻopili 4x2x100ml Paipu PP/PC
mea hoʻopili 4x2x20ml Paipu PP/PC
mea hoʻopili 4x2x8/10ml Paipu PP/PC
Kahi inoa-3

1.Professional centrifuge mea hana, hoʻokūkū kumukūʻai.

2.ISO9001, ISO13485, CE, SFDA Certification, nā mīkini a pau e ho'āʻo maikaʻi i ka maikaʻi a me ka hōʻailona maikaʻi ma mua o ka laweʻana.

3.Long-manawa kākoʻo 'enehana a me ka 'oihana mea kūʻai aku lawelawe ma kela a me keia pae o ka huahana kuai, haawi aku a me ka hana.Our kiʻekiʻe loa qualified a me ka 'ike pūʻulu lawelawe e hoʻolako 'oe i kahi kūlana kūikawā o ke kākoʻo no kou kuai no ka mea, ola a pau.

4. Hiki iā mākou ke hāʻawi aku i nā hoʻoponopono hoʻoponopono no nā koi kūikawā o nā mea kūʻai.

5.Powered me kahi hui kūpono o nā 'enekinia i kākoʻoʻia e nā makahiki o kaʻike ma ko lākou mauʻoihana, e hōʻoiaʻiʻo ana ka hui i kēlā me kēia huahana e haʻalele i ka'āpana hana i ka hōʻailona ma nāʻano a pau.

KA NUI
0
ʻIe hīnaʻi
    Ua make ʻole kāu pahu noiʻi
Hoʻopauninau