All Māhele
Kenekulia Centrifuge

Kenekulia Centrifuge

Home > Nā huahana- TJNE > Nā kenekulia > Kenekulia Centrifuge

ʻO ka Micro centrifuge i hoʻopaʻa ʻia i ka wela kūpono no nā laʻana centrifuge like ʻole

noi: Nā kaʻa hōʻiliʻili koko, Nā hale hōʻiliʻili koko
Māmā 6000 rpm
Max.RCF 4860xg
Max.Capacity 4*100ml swing bākeke rotor
Nā Rotor Kaulike ʻO nā rotor kihi paʻa + Holoi i waho rotor
make LCD, hōʻike pale kala ʻelima ʻīniha
Model Number: KCL-60R
palapala hoʻomaikaʻi: CE, ISO13485, ISO9001, SFDA
palapala hoʻokō 1 makahiki palapala hoʻokō no ka mīkini holoʻokoʻa, 3 makahiki palapala hoʻokō no ka compressor a me 5 makahiki palapala hoʻokō no ka kaʻa. Nā ʻāpana pani manuahi a me ka hoʻouna ʻana i loko o ka palapala hōʻoia.
  • Description
  • Nā Kūlana Kiʻi
  • Rotors a me na mea komo
  • ʻO ka pono kūpono

Hiki ke hoʻohana ʻia nā kaʻa a i ʻole nā ​​hale hōʻiliʻili koko e nā ʻano limahana like ʻole, no laila ʻo ka microcentrifuge KCL-60R i hoʻolālā ʻia no kēia kumu he wikiwiki a me ka pono, me nā wikiwiki wili kiʻekiʻe a me nā manawa pōʻaiapuni pōkole, maʻalahi e hoʻohana a maʻalahi hoʻi. Loaʻa iā ia nā hoʻonohonoho i hoʻolālā mua ʻia e maʻalahi ai ke wili pololei i ke koko. Hoʻoponopono koke ia i ke koko e hōʻoia i kona ola no ka hoʻohana lapaʻau. Hoʻolako ʻia me 4 x 100ml rotor horizontal, nā paipu centrifuge nucleic acid koho, nā paipu hōʻiliʻili koko vacuum, 15ml, 10ml, 8ml, 5ml, 2ml a me nā mea hoʻololi paipu centrifuge ʻē aʻe.

Design

● Metala hale, metala poʻi, a me kuhiliʻole kila centrifuge keʻena he autoclave-hiki a kūpaʻa detergents a me disinfection wai.

● puka makani nānā ma ka poʻi no ka hoʻoponopono ʻana i ka wikiwiki a me ke ana kani.

● Ka mana microprocessor me ka hoʻololi pinepine ʻana i ka kaʻa kaʻa AC.

● E hoʻohana i ka ʻōnaehana hoʻomaʻalili palekana kaiapuni kiʻekiʻe, ʻaʻohe haumia kaiapuni, ka mana wela kiʻekiʻe.

● LCD

● Pale paʻi LCD me ka ʻaoʻao maʻalahi a maopopo, hōʻike i nā palena āpau o ka hana o ka mea hana, hiki i ka mea hoʻohana ke hoʻonohonoho i ka wikiwiki centrifugal a me ka manawa centrifugal me ka manaʻo ʻole.

● ʻO ka ʻōnaehana hana Centrifuge me ka ʻōlelo huna e pale aku i ka hoʻohana pono ʻole ʻana, ka pilina USB waho, hiki ke hahai a huli i nā ʻāpana he 1000 o ka ʻikepili centrifugal.

● Māmā ke kaumaha, liʻiliʻi ka nui, maʻalahi, nani a lokomaikaʻi hoʻi ke ʻano, hiki i nā wāwae kīʻaha omo kū hoʻokahi ke hopu paʻa i ka ʻili o ke kau ʻana, ʻoiai ke hoʻokele nei me ka hopohopo ʻole e pili ana i ka neʻe ʻana o ka centrifuge.

● Hiki ke hoʻololi ʻia nā wāwae kīʻaha omo ʻehā i ke kiʻekiʻe a me ka haʻahaʻa, ʻoiai ke kūkulu ʻia ʻana o ka centrifuge i loko o ka pae, hiki nō ke hoʻololi i ke kaʻa hōʻiliʻili koko i ka hihia o ka ʻāina ʻaʻole like me ka ʻāina i ka centrifuge i kahi kūlana paʻa o ka hoʻohana ʻana, ʻo ka hopena centrifugal maikaʻi loa, ka hoʻohana ʻana i ka palekana.

● Ua hoʻolako ʻia me 4 x 100ml rotor horizontal, nā paipu centrifuge nucleic acid koho, nā paipu hōʻiliʻili koko vacuum, 15ml, 10ml, 8ml, 5ml, 2ml a me nā mea hoʻololi paipu centrifuge ʻē aʻe.

KCL-60R Microcentrifuge Paʻahau Haʻahaʻa

Mea launa hoʻohana

● ʻŌnaehana hoʻomaʻalili ʻole CFC, hana nā rotors hoʻomaʻalili mua i ka wā e kali ana, ka mana wela pololei a hiki i ka – 9°C.

● Programmable a storable, hale kūʻai a hiki i 1000 polokalamu a hāʻawi pololei mea hoʻohana me ka hoʻokahi kī kī. ʻO ka ʻāpana i mālama ʻia: hoʻomau ka hui ʻana i ka hoʻomanaʻo ma hope o ka pau ʻana o ka centrifugation.

● Hoʻopaʻa paʻa ʻakomi a paʻa i ka wā holo rotor

● Hiki ke hoʻololi i nā rotors

● Hoʻoponopono pilikia 'akomi me ka hōʻike ʻana i ka helu kuhi hewa a me ka hoʻāla ma ka pale.

● ʻenehana palapala sila "Mute". Me ka palapala hōʻoia "palapala sila" haʻahaʻa walaʻau, ʻo ka walaʻau hana wikiwiki loa ma lalo o 50 decibels.

KCL-60R Microcentrifuge Paʻahau Haʻahaʻa

Maukele

● Hana ʻia e like me nā lula palekana honua (e laʻa me IEC 61010)

● Palekana Uila pani pani, ʻaʻole hiki ke wehe ʻia ka puka i ka wā e holo ana ka rotor a ʻaʻole holo ka mīkini i ka wehe ʻana o ka poʻi a ʻike ʻia ke code hewa.

● Hoʻokuʻu ʻia ka poʻi ulia pōpilikia ke pio ka mana.

● Hine kinoea no ka pale hāʻule ʻana o ke poʻi.

● Hana ʻia nā pale palekana no ka wikiwiki, ma luna o ka hoʻomehana (motor, chamber), imbalance etc e hōʻoia i ka palekana o ka mīkini kanaka.

KCL-60R Microcentrifuge Paʻahau Haʻahaʻa
Laulā māmā (rpm) 6000r / min ʻO ka wikiwiki ± 10r / min
Laulā RCF (xg) 4860xg Kaha Nui (ml) 4 × 100ml
Hoʻololi i ka manawa 0~99h59min59s Noise (dBA) < 50dB
ʻŌhumu mana kūhelu wela -9 ℃ ~ + 40 Ka pololei o ka hoʻomalu ʻana o ka wela ± 1
Uuna paona (me ka rotor ole) 42kg LCD Hōʻike pale nui ʻelima ʻīniha
Lako ikehu AC220V 50hz 10A, 500W Ana (mm) 640 × 340 × 370mm (L × W × H)
ʻAʻole. Rotor Max.Capacity Max. ʻo ka wikiwiki Max. RCF palapala aie
NO.16 Rotor kihi 24 × 10 / 8ml 6000r / min 4860xg Paipu PP/PC/ʻakika nucleic
mea hoʻopili 24 × 5ml
mea hoʻopili 24 × 2ml
NO.24 Bākeke swing 4 × 100ml 5000r / min 3437xg kīʻaha huinaha
mea hoʻopili 4×5×5ml
mea hoʻopili 4×4×10/8ml
Kahi inoa-3

1. Mea hana centrifuge ʻoihana, kumu kūʻai hoʻokūkū.

2. ISO9001, ISO13485, CE, SFDA Certification, nā mīkini a pau e ho'āʻo maikaʻi loa a me ka hōʻailona maikaʻi ma mua o ka laweʻana.

3. ʻO ke kākoʻo ʻenehana lōʻihi a me ka lawelawe ʻoihana ʻoihana i kēlā me kēia manawa o ke kūʻai aku ʻana o ka huahana, ka hāʻawi ʻana a me ka hana. ʻO kā mākou pūʻulu lawelawe mākaukau a mākaukau e hāʻawi iā ʻoe i kahi kūlana kūʻokoʻa o ke kākoʻo no kāu kūʻai ʻana no kona ola holoʻokoʻa.

4. Hiki iā mākou ke hāʻawi i nā hāʻina i hoʻopilikino ʻia no nā koi kūikawā o nā mea kūʻai aku.

5. Hoʻoikaikaʻia me ka hui maikaʻi o nā mea'enekini i kākoʻoʻia e nā makahiki o kaʻike ma kā lākou mauʻoihana pono'ī, e hōʻoia ka hui i kēlā me kēia huahana e haʻalele i ka'āpana hana i ka hōʻailona ma nāʻano a pau.

KA NUI
0
ʻIe hīnaʻi
    Ua make ʻole kāu pahu noiʻi
Hoʻopauninau