All Māhele
Centrifuge i hoʻopaʻa ʻia

Centrifuge i hoʻopaʻa ʻia

Home > Nā huahana- TJNE > Nā kenekulia > Centrifuge i hoʻopaʻa ʻia

ʻO Centrifuge Haʻahaʻa Haʻahaʻa me ka hoʻokaʻawale pololei loa

noi: ʻO nā waihona koko, nā hale hoʻololi, nā lāʻau lapaʻau, Biotechnology
Māmā 8000 rpm
Max.RCF 14900xg
Max.Capacity 6 * 2400ml
ʻŌhumu mana kūhelu wela -20 ℃ ~ + 40
Nā Rotor Kaulike Nā Rotor Swing
make LCD
Model Number: CVR-80B
palapala hoʻomaikaʻi: CE, ISO13485, ISO9001, SFDA
palapala hoʻokō 1 makahiki palapala hoʻokō no ka mīkini holoʻokoʻa, 3 makahiki palapala hoʻokō no ka compressor a me 5 makahiki palapala hoʻokō no ka kaʻa. Nā ʻāpana pani manuahi a me ka hoʻouna ʻana i loko o ka palapala hōʻoia.
  • Description
  • Video
  • Nā Kūlana Kiʻi
  • Rotors a me na mea komo

He centrifuge kū papahele ka CVR-80B i hoʻolālā kūikawā ʻia no ka hoʻohana ʻana i nā waihona koko a me nā hale hoʻoili koko. Me ka nui o nā ʻeke koko he ʻumikūmālua 500 ml i kēlā me kēia holo, hiki iā ia ke hana pono i nā nui o nā laʻana. Hāʻawi ka centrifuge i nā hopena sedimentation maikaʻi loa a hiki ke hana hou ʻia mahalo i kona holo mālie loa.

He mea pono, hana kiʻekiʻe kiʻekiʻe koko centrifuge.

Hiki ke hoʻololi pololei ʻia ka ʻōnaehana hoʻoheheʻe kiʻekiʻe ma luna o ka pae wela mai -20°C a +40°C. Hiki i ka Rapid Temp ke ho'olu'u wikiwiki i ke ke'ena centrifuge a me nā mea pono e ho'oma'alili mua i kahi mahana i ho'ākāka 'ia, he mea ko'iko'i loa ia i ka wā e hana ai me nā 'eke koko i ho'omaha mua.

Design

● Kiʻekiʻe kiʻekiʻe kiʻekiʻe kila kila me ka kila pahū-hōʻoia pale lima lima, ekolu papa o ka pale, palekana a me ka hilinaʻi. ʻO 304 # ke keʻena kila kila he autoclave-hiki a kūpaʻa i nā detergent a me nā wai disinfection.

● Ua hana ʻia ke kino rotor me ka alumini LC4 maʻamau o ka mokulele mokulele, ua hana ʻia a hoʻohālikelike ʻia ma hope o ka hoʻomaʻamaʻa ʻana a me ka ʻike ʻana i ka hemahema o ka pae A-level, a ua hala i ka hoʻāʻo ʻana i ke koena a me ka hoʻāʻo ʻana i ke kaulike.

● puka makani nānā ma ka poʻi no ka hoʻoponopono ʻana i ka wikiwiki a me ke ana kani.

● Microprocessor mana me kalapona brushless nui torque alapine hoʻololi kaʻa, mālama-noa, ʻaʻohe lepo haumia.

● Pūnaehana hoʻokele maʻalahi e hoʻokele pololei i ke poʻo rotor, holo mālie, haʻalulu liʻiliʻi, haʻahaʻa haʻahaʻa.

● Hōʻike ka LCD i nā ʻāpana o ka Speed, Timer, RCF, Rotors, Program(Memory), Acceleration & Deceleration information and Error code information.

● ʻO ke apo hoʻopaʻa paʻa pālua i hana ʻia no ka poʻi centrifuge a me ka mea kani e mālama i ka sila maikaʻi lōʻihi.

● a hiki i 12 mau eke o 500 ml koko holookoa i ka manawa hookahi, he kaawale o 14400ml o specimens.

● Me ka pale pale makani, e uhi ana i ka rotor a kōkua i ka pale ʻana i nā au o ka ea mai ka hoʻopili ʻana i nā specimens e hana ʻia.

CVR-80B

Mea launa hoʻohana

● CFC free refrigeration system, double-cycle refrigeration, heating and cooling double-loop control, ikaika ka wela a me ke anu, aole pollution kaiapuni, precise temperature control.

● Hiʻohiʻona mua-hoʻoluʻu, Ka hoʻomalu wela pololei a hiki i - 20°C.

● Programmable a storable, hale kūʻai a hiki i 30 polokalamu a hāʻawi pololei mea hoʻohana me ka hoʻokahi kī kī. ʻO ka ʻāpana i mālama ʻia: hoʻomau ka hui ʻana i ka hoʻomanaʻo ma hope o ka pau ʻana o ka centrifugation.

● Hāʻawi i ka 10 acceleration rates a me 10 braking ramp, i mea e pale pono ai i ka sedimentation lua, me ka hopena centrifugation maikaʻi.

● Hoʻopaʻa paʻa ʻakomi a paʻa i ka wā holo rotor

● Hiki ke hoʻololi i nā rotor, mea hoʻohui rotor kūikawā e maʻalahi ai ka hoʻouka a me ka wehe ʻana i ka rotor.

● Hoʻoponopono pilikia 'akomi me ka hōʻike ʻana i ka helu kuhi hewa a me ka hoʻāla ma ka pale.

● "Mute" ʻenehana patent. ʻO ka haʻahaʻa haʻahaʻa o ka walaʻau ma mua o 58 decibel ma ka wikiwiki hoʻololi kiʻekiʻe.

● Huli 'akomi rpm/rcf

● ʻO ka ʻōnaehana hōʻike rotor maʻamau, ʻo ka ʻike rotor coded e pale i ka rotor mai ka holo wikiwiki ʻana.

CVR-80B-8

Maukele

● Hana ʻia e like me nā lula palekana honua (e laʻa me IEC 61010)

● Palekana Uila pani pani, ʻaʻole hiki ke wehe ʻia ka puka i ka wā e holo ana ka rotor a ʻaʻole holo ka mīkini i ka wehe ʻana o ka poʻi a ʻike ʻia ke code hewa.

● Hoʻokuʻu ʻia ka poʻi ulia pōpilikia i ka wā pau ʻole o ka mana (pono loa i ka pau ʻana o ka mana i manaʻo ʻole ʻia).

● Hine kinoea no ka pale hāʻule ʻana o ke poʻi.

● Hana ʻia nā palekana no ka wikiwiki loa, ka hoʻomehana nui ʻana (motika, keʻena), ke kaulike ʻole a pēlā aku e hōʻoia i ka palekana o ka mīkini kanaka.

CVR-80B-802

Laulā māmā (rpm) 0-8000rpm hiki ke hoʻololi ʻO ka wikiwiki ± 20r / min
Kaha Nui (ml) 6 * 2400ml Kaulana wela(℃) -20 ℃ ~ + 40 ℃ hiki ke hoʻololi
Laulā RCF (xg) 0-14900xg hiki ke hoʻololi ʻO ke kūpono o ka mahana ± 1
Hoʻololi i ka manawa 1-99h59minutes hiki ke hoʻololi ʻO ka wikiwiki / hoʻemi ʻana 1-- 12
Noise (dBA) 65 ~ 68dB (A) Papahana hoʻohana i kēlā me kēia lā 30
Ana 1000 × 850 × 1180mm (L × W × H) Uuna paona (me ka rotor ole) 500KGS
make LCD Lako ikehu AC220V,50HZ,30A
Kāohi a hoʻokele i ka microprocessor ʻO ka mīkini AC Brushless me ka torque nui a me ka hoʻololi pinepine, ka mana microprocessor
ʻAʻole. Rotor nona iho Speed RCF

NO.1

4

Rotor Angle 6 × 1000ml 8000r / min 14900xg

NO.2



Rotor Swing 6 × 2400ml 4000r / min 5330xg

NO.3

2

Rotor Swing 6×2×1000ml 4000r / min 5800xg
KA NUI
0
ʻIe hīnaʻi
    Ua make ʻole kāu pahu noiʻi
Hoʻopauninau