NA HALE KUPUNI
Haʻahaʻa māmā Benchtop Centrifuge Brushless Motor Safty Lid Laka
| noi: | Nā halemai, nā keʻena lapaʻau holoholona, nā keʻena meaʻai, nā kulanui a me nā koleke, nā keʻena lāʻau lapaʻau, nā keʻena moʻomeheu cell, nā keʻena keiki. |
| Māmā | 4000 rpm |
| Max.RCF | 2268xg |
| Max.Capacity | 6*50ml koki rotor |
| Nā Rotor Kaulike | Nā rotors kihi paʻa |
| make | LCD |
| Model Number: | KC40-T |
| palapala hoʻomaikaʻi: | CE, ISO13485, ISO9001, SFDA |
| palapala hoʻokō | 1 makahiki palapala hoʻokō no ka mīkini holoʻokoʻa, 3 makahiki palapala hoʻokō no ka compressor a me 5 makahiki palapala hoʻokō no ka kaʻa. Nā ʻāpana pani manuahi a me ka hoʻouna ʻana i loko o ka palapala hōʻoia. |
- Description
- Video
- Nā Kūlana Kiʻi
- Rotors a me na mea komo
- ʻO ka pono kūpono
Loaʻa ka benchtop centrifuge KC40-T me nā rotors paʻa-kihi he nui. Hiki i ka laulā o nā mea pono ke hoʻokomo i nā paipu mai 2 ml a 50 ml. ʻO ka RCF kiʻekiʻe loa ma mua o 2,680 x g he kūpono ia no nā wahi noi he nui i nā diagnostics lapaʻau, ka lāʻau lapaʻau holoholona, nā lāʻau lapaʻau, ka nānā ʻana i ke kaiapuni a me ka hana ʻoihana, a me nā kulanui a me nā hale noiʻi.
Design
● ʻO ka hale metala, ka poʻi metala, a me ka keʻena centrifuge 304# he mea hiki ke hiki ke hiki i ka autoclave a me nā wai hoʻomaʻemaʻe kūʻokoʻa.
● Aluminum alloy rotor.
● ʻO ka puka makani ʻike ma ka poʻi no ka hoʻoponopono ʻana i ka wikiwiki a me ke ana leo.
● Ka mana microprocessor me ka moko DC brushless me ka mālama ʻole.
● Hōʻike ka LCD i nā ʻāpana o Speed, Timer, RCF.

Mea launa hoʻohana
● Hoʻopaʻa paʻa ʻakomi a paʻa i ka wā holo rotor.
● Hiki ke hoʻololi i nā rotors.
● Hoʻoponopono pilikia 'akomi me ka hōʻike ʻana i ka helu kuhi hewa a me ka hoʻāla ma ka pale.
● "Mute" ʻenehana patent. ʻO ka haʻahaʻa haʻahaʻa o ka walaʻau ma mua o 55 decibel ma ka wikiwiki hoʻololi kiʻekiʻe.

Maukele
● Hana ʻia e like me nā lula palekana honua (e laʻa me IEC 61010)
● Palekana Uila pani pani, ʻaʻole hiki ke wehe ʻia ka puka i ka wā e holo ana ka rotor a ʻaʻole holo ka mīkini i ka wehe ʻana o ka poʻi a ʻike ʻia ke code hewa.
● Hoʻokuʻu ʻia ka poʻi ulia pōpilikia ke pio ka mana.
● Hine kinoea no ka pale hāʻule ʻana o ke poʻi.
● Ua hana ʻia nā pale palekana no ka ʻoi aku o ka wikiwiki, ke kaulike ʻole a me ka hōʻoia ʻana i nā hewa kaʻa a me nā mea ʻē aʻe e hōʻoia i ka palekana o ka mīkini kanaka.

| Laulā māmā (rpm) | 0-4000rpm hiki ke hoʻololi | ʻO ka wikiwiki | ± 10rpm |
| Kaha Nui (ml) | 12 * 20ml | Laulā RCF (xg) | 0-2680xg hiki ke hoʻololi |
| Noise (dBA) | ≦55dB(A) | Hoʻololi i ka manawa | 0-99minutes hiki ke hoʻololi |
| Ana (mm) | 430x320x250mm | Uuna paona (me ka rotor ole) | 18KGS |
| Lako ikehu | AC220V, 50HZ, 5A, 120W | ||
| ʻAʻole. | Rotor | nona iho | Max. ka wikiwiki | Max.RCF | palapala aie |
NO.1
|
Rotor kihi | 24 × 10 / 5ml | 4000r / min | 2680xg | ʻO ka paipu PP/PC / ʻO nā paipu hōʻiliʻili koko |
| mea hoʻopili | 24 × 2ml | ||||
| mea hoʻopili | 24 × 1.5ml | ||||
NO.2
|
Rotor kihi | 6×50 ml | 4000r / min | 2680xg | Paipu PP/PC |
| mea hoʻopili | 6 × 15 / 10ml | ||||
| mea hoʻopili | 6 × 5 / 2ml | ||||
![]() | |||||
1. Mea hana centrifuge ʻoihana, kumu kūʻai hoʻokūkū.
2. ISO9001, ISO13485, CE, SFDA Certification, nā mīkini a pau e ho'āʻo maikaʻi loa a me ka hōʻailona maikaʻi ma mua o ka laweʻana.
3. ʻO ke kākoʻo ʻenehana lōʻihi a me ka lawelawe ʻoihana ʻoihana i kēlā me kēia manawa o ke kūʻai aku ʻana o ka huahana, ka hāʻawi ʻana a me ka hana. ʻO kā mākou pūʻulu lawelawe mākaukau a mākaukau e hāʻawi iā ʻoe i kahi kūlana kūʻokoʻa o ke kākoʻo no kāu kūʻai ʻana no kona ola holoʻokoʻa.
4. Hiki iā mākou ke hāʻawi i nā hāʻina i hoʻopilikino ʻia no nā koi kūikawā o nā mea kūʻai aku.
5. Hoʻoikaikaʻia me ka hui maikaʻi o nā mea'enekini i kākoʻoʻia e nā makahiki o kaʻike ma kā lākou mauʻoihana pono'ī, e hōʻoia ka hui i kēlā me kēia huahana e haʻalele i ka'āpana hana i ka hōʻailona ma nāʻano a pau.

EN
AR
BG
HR
CS
DA
NL
FI
FR
DE
EL
IT
JA
KO
NO
PL
PT
RO
RU
ES
SV
CA
TL
IW
ID
LV
LT
SR
SK
SL
VI
SQ
HU
MT
TH
TR
FA
AF
MS
GA
BE
AZ
KA
MN
KK
UZ

















