Māmā16500 rpm
Max.RCF19480xg
Max.Capacity4 * 100ml i hoʻopaʻa ʻia i ka rotor kihi
Nā Rotor KaulikeNā rotors kihi paʻa
makeLCD
Model Number:TG16-WS
palapala hoʻomaikaʻi:CE, ISO13485, ISO9001, SFDA
palapala hoʻokō1 makahiki palapala hoʻokō no ka mīkini holoʻokoʻa, 3 makahiki palapala hoʻokō no ka compressor a me 5 makahiki palapala hoʻokō no ka kaʻa. Nā ʻāpana pani manuahi a me ka hoʻouna ʻana i loko o ka palapala hōʻoia.
  • Description
  • Video
  • Nā Kūlana Kiʻi
  • Rotors a me na mea komo
  • ʻO ka pono kūpono

ʻO kā mākou centrifuge wikiwiki TG16-WS Loaʻa iā ia kahi ākea o nā rotors kihi paʻa, hiki i kēia centrifuge āpau ke hoʻopaʻa i nā paipu PCR, nā paipu hoʻāʻo, nā paipu lalo poepoe, a hāʻawi ia i ka mana kupaianaha me 4 x 100 ml i loko o kahi rotor kihi paʻa.

Me ka nui o nā rotors a me nā mea komo a me nā waiwai RCF kiʻekiʻe a hiki i 23,120 x g, kūpono ia no nā ʻano noi like ʻole.

Design

● Metala hale, metala poʻi, a me kuhiliʻole kila centrifuge keʻena he autoclave-hiki a kūpaʻa detergents a me disinfection wai.

● puka makani nānā ma ka poʻi no ka hoʻoponopono ʻana i ka wikiwiki a me ke ana kani.

● Ka mana microprocessor me ka hoʻololi pinepine ʻana i ka kaʻa kaʻa AC

● LCD Hōʻike i nā palena o ka Speed, Timer, RCF, Rotors, Program(Memory), Acceleration & Deceleration information and Error code information.

● ʻO ke apo hoʻopaʻa paʻa pālua i hana ʻia no ka poʻi centrifuge a me ka mea kani e mālama i ka sila maikaʻi lōʻihi.

ʻO ka Centrifuge wikiwiki kiʻekiʻe ma luna o ka papaʻaina T16-M

Mea launa hoʻohana

● 3 pae damping no ka anti vibration. Hiki ke hoʻopaʻa ʻia a mālama ʻia, mālama i nā polokalamu he 30 a hāʻawi i ka mea hoʻohana pololei me ka mālama kī hoʻokahi. ʻO ka ʻāpana i mālama ʻia: hoʻomau ka hui ʻana i ka hoʻomanaʻo ma hope o ka pau ʻana o ka centrifugation.

● Hāʻawi i ka 10 acceleration rates a me 10 braking ramp, i mea e pale pono ai i ka sedimentation lua, me ka hopena centrifugation maikaʻi.

● Hoʻopaʻa paʻa ʻakomi a paʻa i ka wā holo rotor

● Hiki ke hoʻololi i nā rotor, mea hoʻohui rotor kūikawā e maʻalahi ai ka hoʻouka a me ka wehe ʻana i ka rotor.

● Hoʻoponopono pilikia 'akomi me ka hōʻike ʻana i ka helu kuhi hewa a me ka hoʻāla ma ka pale.

● "Mute" ʻenehana patent. ʻO ka haʻahaʻa haʻahaʻa o ka walaʻau ma mua o 58 decibel ma ka wikiwiki hoʻololi kiʻekiʻe.

● ʻO ka wikiwiki a hiki i ka 16500rpm ma muli o ke ʻano rotor

ʻO ka Centrifuge wikiwiki kiʻekiʻe ma luna o ka papaʻaina T16-M

Maukele

● Hana ʻia e like me nā lula palekana honua (e laʻa me IEC 61010)

● Palekana Uila pani pani, ʻaʻole hiki ke wehe ʻia ka puka i ka wā e holo ana ka rotor a ʻaʻole holo ka mīkini i ka wehe ʻana o ka poʻi a ʻike ʻia ke code hewa.

● Hoʻokuʻu ʻia ka poʻi ulia pōpilikia ke pio ka mana.

● Hine kinoea no ka pale hāʻule ʻana o ke poʻi.

● Hana ʻia nā pale palekana no ka wikiwiki, ma luna o ka hoʻomehana (motor, chamber), imbalance etc e hōʻoia i ka palekana o ka mīkini kanaka.

ʻO ka Centrifuge wikiwiki kiʻekiʻe ma luna o ka papaʻaina T16-M

Laulā māmā (rpm)0-16500rpm hiki ke hoʻololiʻO ka wikiwiki± 10rpm
Kaha Nui (ml)4 * 100mlLaulā RCF (xg)0-19480xg hiki ke hoʻololi
make7” LCDHoʻololi i ka manawa0-99 mau minuke hiki ke hoʻololi ʻia
Noise (dBA)≦58dB(A)ʻO ka wikiwiki / hoʻemi ʻana i nā helu0-- 9
Ana (mm)485x350x310mmHawaiimīkini hoʻololi pinepine
Uuna paona (me ka rotor ole)28KGSLako ikehuAC220V, 50HZ, A, 600W
ʻAʻole.Rotornona ihoMax. ka wikiwikiMax.RCFpalapala aie
NO.13Rotor kihi12 × 1.5 / 2.2ml16500r / min19175xgPaipu PP/PC
mea hoʻopili12 × 0.5 / 0.2mlPaipu PP/PC
NO.24Rotor kihi12 × 5ml16500r / min19480xgPaipu PP/PC
mea hoʻopili12 × 1.5mlPaipu PP/PC
NO.35Rotor kihi12 × 10ml12000r / min16480xgPaipu PP/PC
mea hoʻopili12 × 5mlPaipu PP/PC
NO.46Rotor kihi24 × 1.5 / 2.2ml14000r / min17530xgPaipu PP/PC
mea hoʻopili24 × 0.5 / 0.2mlPaipu PP/PC
NO.57Rotor kihi36 × 1.5 / 2.2ml13000r / min15400xgPaipu PP/PC
mea hoʻopili36 × 0.5 / 0.2mlPaipu PP/PC
NO.68Rotor kihi12×8×0.2ml15000r / min23120xgNā ʻāpana PCR 8-tube
NO.79Rotor kihi10 × 15ml11000r / min14745xgPaipu PP/PC
mea hoʻopili10 × 10mlPaipu PP/PC
mea hoʻopili10 × 5mlPaipu PP/PC
mea hoʻopili10 × 1.5mlPaipu PP/PC
NO.810Rotor kihi6 × 50ml11000r / min12175xgPaipu PP/PC
mea hoʻopili6 × 15 / 10mlPaipu PP/PC
mea hoʻopili6×3×1.5mlPaipu PP/PC
NO.911Rotor kihi4 × 100ml10000r / min10975xgPaipu PP/PC
mea hoʻopili4 × 50mlPaipu PP/PC
mea hoʻopili4 × 15 / 10mlPaipu PP/PC
mea hoʻopili4 × 5 / 1.5mlPaipu PP/PC
1683516328951323

1. Mea hana centrifuge ʻoihana, kumu kūʻai hoʻokūkū.

2. ISO9001, ISO13485, CE, SFDA Certification, nā mīkini a pau e ho'āʻo maikaʻi loa a me ka hōʻailona maikaʻi ma mua o ka laweʻana.

3. ʻO ke kākoʻo ʻenehana lōʻihi a me ka lawelawe ʻoihana ʻoihana i kēlā me kēia manawa o ke kūʻai aku ʻana o ka huahana, ka hāʻawi ʻana a me ka hana. ʻO kā mākou pūʻulu lawelawe mākaukau a mākaukau e hāʻawi iā ʻoe i kahi kūlana kūʻokoʻa o ke kākoʻo no kāu kūʻai ʻana no kona ola holoʻokoʻa.

4. Hiki iā mākou ke hāʻawi i nā hāʻina i hoʻopilikino ʻia no nā koi kūikawā o nā mea kūʻai aku.

5. Hoʻoikaikaʻia me ka hui maikaʻi o nā mea'enekini i kākoʻoʻia e nā makahiki o kaʻike ma kā lākou mauʻoihana pono'ī, e hōʻoia ka hui i kēlā me kēia huahana e haʻalele i ka'āpana hana i ka hōʻailona ma nāʻano a pau.

KA NUI
0
ʻIe hīnaʻi
    Ua make ʻole kāu pahu noiʻi
Hoʻopauninau