He aha ka RPM Laboratory Centrifuge maikaʻi loa i hoʻohana ʻia no ke koko

Ka manawa paʻi: 2024-10-11 Views: 2320

ʻO ka RPM maikaʻi loa no ka centrifuge laboratory i hoʻohana ʻia no ke koko e pili ana i ka noi kikoʻī (e laʻa, ka hoʻokaʻawale ʻana i ka plasma, serum, a i ʻole nā ​​​​pūnaewele koko). Eia kekahi mau pae RPM maʻamau no nā noi pili koko like ʻole:


1.Plasma/Serum Separation:

No ka plasma maʻamau a i ʻole ka hoʻokaʻawale serum, hana maʻamau nā centrifuges ma waena o 3,000 a 5,000 RPM. Mālama kēia i ka hoʻokaʻawale maʻemaʻe o ka plasma / serum mai nā pūpū koko.


2.Platelet-Rich Plasma (PRP):

No ka unuhi ʻana i ka plasma waiwai nui, hoʻohana pinepine ʻia kahi centrifuge haʻahaʻa haʻahaʻa. ʻO ka RPM maʻamau mai 1,500 a 3,500 RPM. ʻO kahi hoʻolālā kūikawā PRP centrifuge kūpono no ka hoʻokō ʻana i ka hoʻokaʻawale pololei e pono ai no nā kaʻina hana platelet-rich plasma (PRP). Hoʻolālā maʻamau kēia mau centrifuges e hoʻopaʻa i ka hoʻokaʻawale ʻana o nā platelets ʻoiai e mālama ana i ko lākou ola a me ka noʻonoʻo.


3.Whole Blood Processing:

No ka hoʻokaʻawale koko holoʻokoʻa, ʻo ia hoʻi ma nā waihona koko, hiki ke hana nā centrifuges ma 2,500 a 3,500 RPM. Hele mai kekahi mau centrifuges kūikawā me nā hoʻonohonoho wikiwiki hiki ke hoʻonohonoho ʻia, e ʻae ana i nā hoʻoponopono pololei e pili ana i ke ʻano o ka huahana koko e hana ʻia. Ma ia mau hihia, a Kanaka Waihona Koko he koho maikaʻi loa. Hoʻonohonoho pono ʻia kēia mau centrifuges e mālama i nā huahana koko like ʻole, e hāʻawi ana i ka maʻalahi e hoʻoponopono i nā wikiwiki no nā hana e like me ka plasma, ke koko ʻulaʻula, a i ʻole ka hoʻokaʻawale platelet, e hōʻoiaʻiʻo ana i ka pono a me ka pololei.


4. Buffy Coat Isolation:

I ka hoʻokaʻawale ʻana i ka ʻaʻahu buffy, aia nā keʻokeʻo keʻokeʻo a me nā platelets, hana maʻamau ka centrifuge ma kahi o 1,000 a 2,000 RPM.


5.High-Speed ​​Blood Separation:

Ma kekahi mau hoʻonohonoho noiʻi kahi e pono ai ka hoʻokaʻawale pololei ʻana, hiki ke hana nā centrifuges kiʻekiʻe ma 10,000 a 15,000 RPM. Eia naʻe, ʻaʻole maʻamau kēia no nā noi lapaʻau maʻamau.

RPM Laboratory Centrifuge


Nā manaʻo nui:

ʻO ka mea hoʻoheheʻe: ʻO nā laʻana koko e pili ana i ka wela, no laila a centrifuge pahu hau koi pinepine ʻia e mālama i ka pono o ka hāpana, ʻoi loa i ka wā o nā milo lōʻihi.

ʻAno Rotor: Hoʻohana maʻamau ka hoʻokaʻawale ʻana o ke koko i nā rotors swing-out no ka hoʻokaʻawale ʻana a maikaʻi.

RPM Laboratory Centrifuge 2

 

No ka hoʻohana ʻana i ke keʻena hana maʻamau, ʻo ka MKE Lab KC-500B a i ʻole nā ​​hiʻohiʻona like me ka wikiwiki ma waena o 3,000 a 5,000 RPM he koho hilinaʻi no nā hana hoʻoheheʻe koko. Inā loaʻa iā ʻoe nā pono kikoʻī, e like me ka PRP a i ʻole ka hoʻokaʻawale kapa buffy, pono paha ʻoe i kahi hoʻohālike me nā wikiwiki hiki ke hoʻololi ʻia i loko o nā pae i ʻōlelo ʻia. Welina mai e hoʻouna iā mākou i kahi nīnau, a e koho mākou i ke kumu hoʻohālike centrifuge maikaʻi loa no ʻoe.